Showing results: 1921 - 1935 of 2604 items found.
-
HH2107 -
Colluck Company Limited
High Accuracy (Basic Accuracy 0.5%). Jumbo LCD display 2000 count, 21.8mm figure height. Manual Ranging at your choice (30 Range). High Voltage test up to AC 750V and DC 1000V. Higher Current test up to 10A. Resistance test up to 20MΩ. Diode test, audible continuity check and transistor test
-
HH2108 -
Colluck Company Limited
High Accuracy (Basic Accuracy 0.8%). Jumbo LCD display 2000 count, 26mm figure height. Manual Ranging at your choice (30 Range). High Voltage test up to AC 500V and DC 500V. Higher Current test up to 20A AC/DC. Resistance test up to 20MΩ. Erequency test range from 10Hz to 1999Hz
-
Altium Inc.
The PDN Analyzer powered by CST allows you to easily resolve PDN issues as they arise in your board layout process without ever relying on a physical prototype. With digital designs continuing to increase in density and complexity, it's more difficult and critical than ever to fully understand the impact of design decisions on your Power Distribution Network (PDN) voltage and current performance.
-
SM7860 -
HIOKI E.E. Corp
Power Source Unit Ideal for MLCC Leakage Current Measurement. The SM7860 series allows for setting the dual-line output voltage on 8 channels or 16 channels, and enables up to 32-channel of output. The Hioki SM7860-5x/SM7860-6x series is a 32-channel, 500V / 1000V power source for the Hioki SM7810 Super Megohm Meter, providing positive and negative polarities required for MLCC test lines.
-
UEP10M52-53 / CEP10M52-53 -
W-IE-NE-R, Plein & Baus GmbH
The UEP10M52 series is a UEP10M variation with a maximum current output on +6V or -6V (asymmetric) and without +/-12V for use in CERN type CAMAC crates with a maximum 650W power output. The power supply has all the standard features of the UEP10 family as high precision and lowest noise DC outputs and a cut-off protection for overload, over- / and under voltage and over temperature failures.
-
Shenzhen UYIGAO Electronic Technology Co., Ltd
*This MultiMeter is a handheld digital multimeter, high reliability and portability, a perfect tool for the laboratory, factory and home.*It can measure AC/DC voltage, AC/DC current, resistance, capacitance, frequency, duty cycle, diode, continuity, NCV and temperature.*Moreover, more advantages such as backlight, data hold, auto range, true RMS, auto power off, low battery indication and over range indication.
-
AMPTEC RESEARCH
Digital Multimeter is used to measure stray voltage and current in harsh weather environments. Additionally, all internal circuits are conformal coated, it contains an internal all-metal Faraday cage, and has a built-in self-test to ensure ultimate integrity of measurement. The 601ES DMM is NASA Range Safety Board and USAF Space Wing Board approved, proving its intelligent design is ultra-safe.
-
Setfos -
FLUXiM
Easily calculate the short circuit current, open circuit voltage Voc and fill factor with Setfos. Tweak the layer stack and add light scattering layers for enhanced absorption. Optimize for AM1.5 or specific wavelength bandsElectrical IV curvesCurve fitting & parameter extractionAC simulation and transient experiments like photo-CELIVAdvanced device physics: SRH-recombination, excitons, ... Design anti-reflection coatings or transparent cells
-
NEO TELE-TRONIX PVT. LTD
This modern Test Set For Instrument Transformer is used for measuring relative errors of Instrument Voltage and Current Transformers. This is developed for reading out the unbalance of any bridge circuit. It also calculates the burden associated to the test sample. In addition to this, it further converts it to ratio and phase error values for presenting them on a LCD screen. With high-tech microprocessor controller, it ensures to provide quick and correct measurements.
-
DER EE Electrical Instrument
Meter DimensionPlease indicate meter size Internal Resistance250 , 650, 750, 1200 Sensitivity200A , 250A , 500A, 1mA Pointer ColorAs your color request Scale PlateCustom design according to your drawing LampStandard type is 12V/55mA transparent. If you request special specs., please indicate the voltage and current Install position of the level meterVertical or horizontal Popular spec500A/650
-
Aplab Limited
- 3000W different combination- High current density.- 19″ rack adaptable -5U high- Remote sensing.- Front panel potentiometer to set V&I- 3Digit seven segment display for V&I- High stability and close regulation- Phase controlled preregulation plus linear post regulation Optional, at extra cost- Over voltage protection- 19″ rack mounting
-
Computer Gesteuerte Systeme GmbH
The MCM is designed to drive a variety of brushed motors. This is the CM version of our IMCM. The overload-proof 4-quadrant chopper outputs voltages between 5.5V to 16V up to a constant load of 16A (32A peak). The PWM can be set between 1kHz and 20kHz. The module is protected against undervoltage and overvoltage, shuts down automatically when overheating and is also equipped with a linear current limiting.
-
CM100 -
General Technologies Corp.
Small jaw: 1.2"(W) x 0.53" (D) (300x13.4mm). Clamp opens up to 1/2 inch (12.5 mm). One rotary switch operation. Large 4 digit LCD display. AC/DC Voltage measurement up to 600 Volt. AC/DC current measurement from 0.001 up to 100 A. Relative measurement. One touch auto zero
-
HA1600A -
Aim-TTi
Compliance quality measurements to EN61000-3-2 and EN61000-3-3Measures peak or rms voltage or current, real or apparent power, power factor, phase etc.Tabular/histogram of 40 harmonicsVoltage/current waveforms displaysContinuous analysis with real-time graphical updateWide range of power connectors available320 x 240 pixel high-contrast displayUSB, RS232 and printer interfaces fittedPC control and documentation software supplied (HA-PC-Link+)
-
MCH Instruments Co.,Ltd.
Is a measurement apparatus capable of visually depicting regular changes in electrical activity, such as an electrical current or signal. The resulting data appears as a waveform drawn on a graph with two axes, where the horizontal X axis represents time and the vertical Y axis indicates voltage. In addition, the luminance of the waveform itself is often referred to as the Z axis, which demonstrates the intensity of the activity measured.